NEED HELP

CALL 877.305.0898


Product Overview

Quantity in Basket: None

Code: RH

Starting Price: $1,396.00

Shipping Weight: 26.00 pounds

 
Starting at: $1,396.00USD
Quantity

"RH Class I, Div 2, Industrial Emergency Light"


Features :
  • Suitable for hazardous locations
  • Constructed of impact resistant, fiberglass reinforced polyester
  • Class II, Division 2 rated polycarbonate sealed beam Par 36 tungsten or halogen lamp
  • Maintenance-free, sealed nickel cadmium battery
  • 90 Minutes of emergency illumination
  • Universal 120/277VAC input
  • Automatic low voltage battery disconnect protects battery from deep discharge
  • Automatic brownout protection
  • AC lockout feature reduces installation time
  • Optional self-diagnostic circuit available
  • Momentary test switch and AC ready indicator

Product Details


PRODUCT OVERVIEW: The RH Series is ideal for use in hazardous locations where explosive materials may be present. Constructed from impact resistant, fiberglass reinforced polyester and approved for NEMA 4, 4x, 12 and 13 areas, and in class I, Division 2, Groups A, B, C & D, Zone 2, Groups IIA, IIB, H & IIC areas.


CONSTRUCTION: Constructed of impact resistant, fiberglass reinforced polyester. Housing color is gray and includes stainless steel hardware. Housing is approved for NEMA 4, 4x, 12 and 13 areas, and in class I, Division 2, Groups A, B, C & D, Zone 2, Groups IIA, IIB, H & IIC areas. Viewthrough window allows easy monitoring of AC indicator and optional voltmeter and ammeter. Available with Class II, Division 2 rated polycarbonate sealed beam Par 36 tungsten or halogen lamp heads. Optional shatter-resistant shield for lamp heads is designed for use in food service areas.


ILLUMINATION: Illumination is accomplished with lamp heads mounted on the top of the unit. The Class 1, Div 2 rated lamp head is available in a variety of wattages and is constructed of gray polycarbonate to match the RH Series housing.



BATTERY TECHNOLOGY: Maintenance-free, sealed nickel cadmium battery has an estimated service life of 12 years, and an operating temperature range of 20°F (-7°C) to 95°F (35°C). Maintenance-free, sealed lead calcium battery has an estimated service life of 10 years, and an operating temperature range of 65°F (19°C) to 85°F (30°C). Batteries supply 90 minutes of emergency power.


INSTALLATION: Standard internal mounting or external mounting feet for installation flexibility. The RH series mounts flush against walls.


ELECTRICAL SPECIFICATIONS: Charger Type: Fully automatic, temperature compensating, variable rate float charger
Utility Input: 120/277VAC, 60 Hz. Power Consumption: 15 watts (maximum)
Temperature Range: 20°F (-7°C) to 95°F (35°C) with the sealed nickel cadmium battery, and 65°F (19°C) to 85°F (30°C) with the sealed lead calcium battery.
Recharge Duty Cycle: 24 hours
Load Transfer: A solid state transfer circuit provides load connection.
Controls: Momentary test switch and LED AC-On indicator light
Safety Circuitry: AC Lockout: Prevents battery discharge prior to initial unit power-up saving installation time.
Low Voltage Battery Disconnect: Protects the battery from being severely damaged by deep discharge during prolonged power failures. Brownout Protection: Automatically switches the unit to emergency mode when utility voltage is reduced to the point at which most fluorescent light fixtures would extinguish.


CODE COMPLIANCE: UL 924 listed, NFPA 7O, NFPA 101, NEC and OSHA. Nickel cadmium units additionally UL listed for Class 11, Division 2, Groups F & G applications.


Dimensions

Options


Item Options:
Voltmeter,Ammeter,Auto Test,Food Prep Lenses,Shatter-proof Heads,Special Transformer,Self-test with Alarm


Warranty


Product Characteristics

Value 8
Ease of Installation 8
Maintenance Profile 9
Design Appeal 7
Durability 9

Greentorch products are designed to be versatile and meet the needs of various installation types. It is sometimes difficult to sort through all the options, which is why we developed a rating system to help. The metrics we developed take into account the typical concerns when purchasing a sign such as, the decorative appeal, the amount of upkeep, the level of skill required to install the unit, the lifespan, and how resilient the system is under normal use and abuse. You can use these metrics to search on using our patented UltraSearch system. The ratings for the unit you are currently viewing are below:

Cursor for more info
  • Emergency Power comes from battery pack.
  • Indicates that the device will not ignite an explosion due to being in contact with hazardous dust, liquids, or vapors.
  • Indicates that Incandescent lights such as Halogen, or Tungsten.
  • Indicates that the device has exceptional customization capabilities or is of higher design and performance quality.
  • Indicates that the product includes factory warranty.

Product Attributes

Name RH Class I, Div 2, Industrial Emergency Light

Body Height 16

Body Height 18

Body Width 13.2

Body Width 15.2

Body Depth 6.5

Body Depth 7

Listings UL924 US

Damp Location Rated No

Wet Location Rated No

Light Source Halogen

Light Source Tungsten

Body Material PolyCarbonate

Back Up Power AC Only,Battery Backup

Country Of Origination NA

Mounting Install Type Universal Canopy,Bottom

Includes Battery Yes

Pendant Kit Capable No

AC Current Hz 60

Voltage 120,277

Battery Type Nickel Cadmium,Sealed Lead Calcium

Compliance UL924,NFPA101 Life Safety,OSHA,NEC,NFPA 70

IP65 Rated No

Remote Capable? No

Battery Terminal Type F1

Battery Amperes Hours .27

Battery Amperes Hours .58

Unit Wattage 25,125

Emergency Head Wattage Options 8,12,18,25,30

Max Operation Temperature Celsius 30

Max Operation Temperature Celsius 35

Min Operation Temperature Celsius 19

Min Operation Temperature Celsius -7

Max Operation Temperature 85

Max Operation Temperature 95

Min Operation Temperature 20

Min Operation Temperature 65

Body Color Gray

Standard Lamp Count 1,2,0

Item Options Voltmeter,Ammeter,Auto Test,Food Prep Lenses,Shatter-proof Heads,Special Transformer,Self-test with Alarm

Hazardous Rating Class I

Hazardous Rating Division 2

Hazardous Rating Groups A,IIA,B,IIB,C,11C,D,F,G,H

Battery Volts 6,12

Name RH Class I, Div 2, Industrial Emergency Light

High Res

High Res