Product Overview
Quantity in Basket: None
Code: RB6
Starting Price: $160.00
Shipping Weight: 10.00 pounds
Thermoplastic Industrial Emergency Light
Features :
- Impact-resistant thermoplastic housing.
- Universal J-box mounting pattern
- Illumination provided by Par 36 sealed beam tungsten or halogen lamp heads
- Maintenance free, sealed lead calcium battery or sealed nickel cadmium battery
- Installation flexibility with its J-box mounting pattern and keyhole slots
- 90 Minutes of emergency illumination
- Universal 120/277VAC input
- Automatic low voltage battery disconnect protects battery from deep discharge
- Automatic brownout protection
- AC lockout feature reduces installation time
- Optional self-diagnostic circuit available
- Momentary test switch and AC ready indicator
Product Details
PRODUCT OVERVIEW: The RB6 Series Thermoplastic Emergency Light is a high capacity lighting unit that is easy to install and maintain. Sealed Lead Calcium and Nickel Cadmium battery options allow for multiple of configurations, up to 50 watts. Multiple mounting capabilities make the RB6 a truly universal emergency light. The RB6 features a low profile, push-to-test switch and comes standard with a white finish. Self-diagnostic testing and time delay are some of the many options offered with the RB6. UL 924 Listed.
CONSTRUCTION: Constructed of impact resistant, UL 94 V-0, 5 VA white thermoplastic. Universal J-box mounting pattern, keyhole slots or shelf mounting. Includes a low profile test switch and AC indicator light mounted on the side of unit.
ILLUMINATION: Illumination is accomplished with up to three lamp heads mounted on the top of the unit. A complete offering of Par 36 sealed beam tungsten or halogen lamp heads are available.
BATTERY TECHNOLOGY: Maintenance free, sealed lead calcium battery has an estimated service life of 5 years, and an operating temperature range of 65 F (19 C) to 85 F (30 C). Maintenance free, sealed nickel cadmium battery has an estimated service life of 10 years, and an operating temperature range of 20 F (-7 C) to 95 F (35 C). Batteries supply 90 minutes of emergency power.
INSTALLATION: Provides installation flexibility with its J-box mounting pattern and keyhole slots. Unit can also be shelf-mounted.
ELECTRICAL SPECIFICATIONS: Charger Type: Lead calcium units utilize a solid-state, fully automatic,
voltage regulated charger. Nickel Cadmium units utilize a solid-state, constant voltage charger.
Utility Input: 120/277VAC, 60 Hz.
Temperature Range: 65 F (19 C) to 85 F (30 C) for sealed lead calcium battery. 20 F (-7 C) to 95 F (35 C) for sealed nickel cadmium battery.
Load Transfer: A solid state transfer circuit provides load connection.
Controls: Momentary test switch and LED AC-On indicator light
Safety Circuitry:
AC Lockout: Prevents battery discharge prior to initial unit power-up saving installation time.
Low Voltage Battery Disconnect: Protects the battery from being severely damaged by deep discharge during prolonged power failures.
Brownout Protection: Automatically switches the unit to emergency mode when utility voltage is reduced to the point at which most fluorescent light fixtures would extinguish.
CODE COMPLIANCE: UL 924 listed, NFPA 101, NEC, BOCA, OSHA and IBC illumination standards. Optional Damp Location listings available.
Dimensions

Options
Item Options:
Voltmeter,Ammeter,Time Delay,Auto Test,Special Transformer,Self-test with Alarm
Warranty
Product Characteristics
Value 8
Ease of Installation 9
Maintenance Profile 8
Design Appeal 7
Durability 8
Greentorch products are designed to be versatile and meet the needs of various installation types. It is sometimes difficult to sort through all the options, which is why we developed a rating system to help. The metrics we developed take into account the typical concerns when purchasing a sign such as, the decorative appeal, the amount of upkeep, the level of skill required to install the unit, the lifespan, and how resilient the system is under normal use and abuse. You can use these metrics to search on using our patented UltraSearch system. The ratings for the unit you are currently viewing are below:
Product Attributes
Name RB6 Thermoplastic Industrial Emergency Light
Body Height 11.5
Body Width 13
Body Depth 4.5
Listings UL924 US
Damp Location Rated No
Wet Location Rated No
Light Source Halogen
Light Source Tungsten
Body Material Thermoplastic
Back Up Power AC Only,Battery Backup
Country Of Origination NA
Mounting Install Type Universal Canopy,Bottom
Includes Battery Yes
Pendant Kit Capable No
AC Current Hz 60
Voltage 120,277
Battery Type Nickel Cadmium,Sealed Lead Calcium
Compliance UL924,NFPA101 Life Safety,OSHA,NEC,NFPA 70
IP65 Rated No
Remote Capable? No
Battery Terminal Type F1
Battery Amperes Hours 0
Unit Wattage 18,50
Emergency Head Wattage Options 5.4,7.2,12,18
Max Operation Temperature Celsius 30
Max Operation Temperature Celsius 35
Min Operation Temperature Celsius 19
Min Operation Temperature Celsius -7
Max Operation Temperature 85
Max Operation Temperature 95
Min Operation Temperature 20
Min Operation Temperature 65
Body Color White
Standard Lamp Count 1,2,3
Item Options Voltmeter,Ammeter,Time Delay,Auto Test,Special Transformer,Self-test with Alarm
Hazardous Rating Class
Battery Volts 6,12
Name RB6 Thermoplastic Industrial Emergency Light
Light Source Incandescent
Voltage 12
Emergency Head Wattage Options 12.5
Light Source Incandescent
Voltage 12
Emergency Head Wattage Options 17.9
Light Source Incandescent
Voltage 6
Emergency Head Wattage Options 5.4
Light Source Incandescent
Voltage 6
Emergency Head Wattage Options 7.2
Light Source Incandescent
Voltage 6
Emergency Head Wattage Options 9
High Res
High Res